F4001 Series Vortex Flow Meter
Datasheet
| Size |
: |
1/2” to 12”(DN15mm to DN300mm) |
| Process Connections |
: |
wafer(standard),Flanged; Insertion; |
| Process temperature |
: |
23~482 °F (-5~+250 °C) (with LCD display) |
| Operating pressure |
: |
232 psi (1.6MPa) std; up to 928 (6.4 MPa) optional |
| Velocity Range |
| Liquids |
: |
2~20ft/s( 0.6~6 m/s). |
| Gas& Steam |
: |
23~ 148ft/s (5~65m/s) |
| Accuracy |
: |
1.0% for liquid; 1.5% for gas and steam |
| Repeatability |
: |
0.33% for liquid, 0.5% for gas |
| Turn down ratio |
: |
10 1 (liquids) |
| Materials |
: |
Stainless steel # 304 |
| Signal output |
: |
Pulse output, 2-wire 4-20mA Dc,Vdc, RS484(Modbus RTU) , HART foundation fieldbus. |
| RAM Back-up |
: |
Lithium Battery, 3.6Vdc |
| Housing protection |
: |
IP65; IP67 for options Class I, Div. 1, Groups B, C and D listed for hazardous zone |
| Display units |
: |
m3/h, kg/hr |
| Keypad |
: |
Rate, Total |
| Power supply |
: |
isolated 14~36 VDC or Battery for local |
| NIST traceable |
: |
YES |
| Data storage |
: |
EPROM storage up to 5 years |
| Data logger |
: |
Reading, sampling Times 0.5 S |